检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:童辉[1] 张荣国[1] 巫辉[1] 陈连喜[1] 雷家珩[1]
出 处:《武汉理工大学学报》2004年第9期20-22,共3页Journal of Wuhan University of Technology
基 金:国家自然科学基金 (5 0 2 72 0 4 8);湖北省自然科学基金 (2 0 0 1ABB0 76)
摘 要:以导光多孔氧化硅玻璃为基片 ,采用溶胶 -凝胶法制得了 V2 O5/ Si O2 载敏 SO2 光化学传感器基体。讨论了载敏试剂浓度对载敏玻璃试样透光性的影响、载敏多孔玻璃的感敏特性及其工作机理。结果表明 ,载敏后的多孔玻璃对 SO2有较好的敏感性 ,载敏剂 V2 O5遇 SO2 后 ,4价钒在 4 90 nm处的特征透光率增加 ,5价钒在 5 90 nm处的特征透光率降低 ;一定的湿度和较高的温度有利于载敏多孔玻璃对 SO2The V 2O 5/SiO 2 porous glass flakes of optical chemical sensors were obtained by sol-gel method, which could detect SO 2. The light transmission of carrier porous glass on the concentration of sensitive reagent was studied. The sensitive characteristic and mechanisms were also investigated. The results showed that the carrier porous glass had high sensitivity to SO 2. The characteristic light transmission of tetravalent vanadium increased in the 490 nm and quinquevalent vanadium reduced in the 590 nm, when the sensitive reagent V 2O 5 was in the condition of SO 2. Humidity and high temperature were beneficial to the detection of SO 2.
分 类 号:TQ17[化学工程—硅酸盐工业]