检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]湘潭工学院环境工程与化工新技术研究所,湖南湘潭411201 [2]湘潭合成化工厂,湖南湘潭411202
出 处:《工业水处理》2004年第6期35-38,共4页Industrial Water Treatment
摘 要:通过对3种有机缓蚀阻垢剂及3种灭藻杀菌剂的筛选,研究了用化学方法处理甲醛生产中循环水系统的结垢和腐蚀问题。生产实践表明,在甲醛生产循环冷却水处理系统中,采用m(TS-609)∶m(HEDP)为1∶2,m(优氯净)∶m(JN-2)为1∶1的有机复合水处理剂、浓缩倍数为3.5、QM/QR=8.3%、QB/QR=6.3%、水中阻垢缓蚀剂总质量浓度为12mg/L等操作参数,不仅在阻垢缓蚀方面取得了明显效果,而且可大幅度节省水的消耗。Through the selection of 3 kinds of organic corrosion and scale inhibitors, and 3 kinds of biocide, the corrosion and scale problems of formaldehyde circulating water system treated with chemical method are studied. The production practice shows that it not only obtains obvious effect in the aspect of corrosion and scale inhibition, but also reduces the water consumption greatly through the technological conditions, which mix rate of organic composite water treatment chemicals of TS - 609 to HEDP is 1 ∶ 2 and sodium dichloroisocyanurate to JN - 2 is 1 ∶ 1, concentrating times is 3.5, QM to QR is 8.3%, QB to QR is 6.3%, all concentration of corrosion and scale inhibitor in water is 12 mg/L and so on, are adopted in circulating cooling water system of formaldehyde process.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3