检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中国建筑材料科学研究院 [2]河南理工大学,河南焦作454000
出 处:《混凝土》2004年第10期3-4,24,共3页Concrete
基 金:国家"973"资助项目(编号2001CB610700);河南省自然科学基金(0111040500)
摘 要:高性能混凝土的特点是低水胶比、高胶凝材料用量。本文较系统地研究了低水灰比混凝土的水化程度,未水化胶凝材料后期继续水化对混凝土强度的影响,并采用超声波无损检测技术研究了后期水化对混凝土结构的损伤情况。研究表明低水灰比混凝土中存在大量未水化水泥,其后期继续水化将导致混凝土损伤,抗压强度显著降低,耐久性变差。且水灰比越低,未水化胶凝材料后期继续水化产生的危害越大。Low water-binder ratio and abundant binder are the characters of high performance concrete. Degree of hydration and harm of unhydrous cement on concrete are studied in this paper. The concrete structure is detected by the ultrasonic nondestructive detection instrument. It is shown that there is a lot of anhydrous cement in low water-binder ratio concrete. They result in concrete compressive strength and durability reduction when they continue hydration in later stage. Furthermore, the lower the water-binder ratio is, the severer the concrete deterioration is when anhydrous cement continues hydrating in later stage.
分 类 号:TU528.01[建筑科学—建筑技术科学]