器械消毒液中苯酚的含量测定  被引量:3

Determination of phenol contents in solution of medical appliance disinfectant

在线阅读下载全文

作  者:房德敏[1] 李洁[1] 周永梅[1] 吕鹏[1] 

机构地区:[1]天津医院,天津300211

出  处:《华西药学杂志》2004年第5期385-386,共2页West China Journal of Pharmaceutical Sciences

摘  要:目的 建立器械消毒液苯酚含量的测定方法。方法 采用紫外分光光度法 ,检测波长为 2 70nm。结果 苯酚在12 18~ 4 8 72 μg·ml-1浓度范围内与吸光度呈良好的线性关系 (r =0 9995 )。平均回收率为 99 85 % ,RSD =0 5 0 %。结论 该方法操作简便、快速。OBJECTIVE To establish a method for determination of phenol in the solution of medical appliance disinfectant. METHODS The content of phenol in the solution was determined by UV method at 270 nm. RESULT A good linearity was found between absorbance and concentration in the range of 12.18-48.72 μg·ml -1 (r=0.9995), with average recovery of 99.85% and RSD of 0.50%. CONCLUSION The method is simple, easy and reliable with good repeatability.

关 键 词:器械消毒液 含量测定 紫外分光光度法 RSD 检测波长 测定方法 线性关系 苯酚 酚含量 平均回收率 

分 类 号:R979.7[医药卫生—药品] R286.0[医药卫生—药学]

 