钼兰法分光光度测定异烟肼  被引量:1

Spectrophotometic determination of isoniazide by molybdnum blue method

在线阅读下载全文

作  者:章鹏飞[1] 张玉洲[1] 朱庆仁[1] 刘清理 沈乃葵[2] 

机构地区:[1]淮北煤炭师范学院化学系 [2]蚌埠医学院检验系

出  处:《淮北煤师院学报(自然科学版)》1993年第3期44-48,共5页Journal of Huaibei Teachers College(Natural Sciences Edition)

摘  要:本文报导了在pH为1的酸性介质中,于沸水煮沸条件下,利用磷钼酸铵被异烟肼定量还原为钼兰的水相显色,从而用分光光度法来测定异烟肼含量的方法.该兰色显色液的最大吸收波长位于720nm处,异烟肼含量在0~24μg·ml^(-1)范围内符合比耳定律,其摩尔吸光系数为6.2×10~3 l·mol^(-1)·cm^(-1).本法曾用于异烟肼针剂及片剂中异烟肼含量的测定,其结果与药典法所测得结果基本一致.方法具有试剂易得、简便、准确等优点.A new spectrophotometic method ror the determination of isoniazide was developed. It depends om the reduction of ammonium molybdophosphate to molybdenum blue by isoniazide.In pH =1 acid solution and under heating in boiling water bath, ammonium molybdophosphate is quantitatively reduced by isoniazide to molybdenum blue. The maxinum absorption of the blue complex is at 720 nm and the blue colour is stable for 1 hour. Beers law is obeyed for isoniazide in the concentration range of 0~24μg·ml^(-1)and the molar absorptivty of the complex is 6.2×10~3l·mol^(-1)·cm^(-1).The recommended method is simple,sensitive and accurate and has been applied to the determination of isoniazide content in isoniazide tablets and ampoules. The results of analysis is satisfactory.

关 键 词:分光光度法 钼兰法 异烟肼 

分 类 号:R978.3[医药卫生—药品]

 