基于IEC 61850标准的采样值传输模型构建及映射实现  被引量:71

MODELING AND MAPPING IMPLEMENTATION OF A SAMPLED VALUE MODEL BASED ON IEC 61850

在线阅读下载全文

作  者:殷志良[1] 刘万顺[1] 杨奇逊[1] 秦应力[1] 林达[2] 

机构地区:[1]华北电力大学四方研究所,北京市100085 [2]华北电力大学电力工程系,北京市102206

出  处:《电力系统自动化》2004年第21期38-42,共5页Automation of Electric Power Systems

基  金:国家自然科学基金(50277012)

摘  要:采样测量值的数字化传输是实现变电站自动化系统过程层与间隔层串行通信的重要部分。分析了 IEC 61850标准定义的采样值传输抽象模型,基于 IEC 61850-9-1定义的合并单元,以变压器差动保护所需采样值为研究对象,对采样值传输模型进行具体合理构建,并实现此模型在通信堆栈的映射,揭示了标准中抽象模型与具体映射之间的内在统一关联。The digital transmission of the sampled value is one of the key elements in realizing serial communication between the process level and bay level of the substation automation system. The abstract model of the sampled value defined in IEC 61850 is analyzed. By taking the transformer differential protection as an example, based on the merging unit defined in IEC 61850-9- 1, the sampled value model is constructed in a specific and rational way, with the communication service mapping of this model implemented. As a result. the intrinsic unified relationship between the abstract model and concrete mapping is revealed.

关 键 词:采样值传输模型 IEC 61850 合并单元 逻辑节点零 映射 

分 类 号:TM73[电气工程—电力系统及自动化] TM764

 