运行中的SF_6变压器的气体监督检测  被引量:7

In-service gas monitoring and detection for SF_6 transformers

在线阅读下载全文

作  者:胡红红 周永言[2] 姚唯建[2] 唐峰 

机构地区:[1]广东省广电集团有限公司深圳供电分公司,广东深圳518020 [2]广东省电力试验研究所,广东广州510600

出  处:《广东电力》2004年第5期78-81,共4页Guangdong Electric Power

摘  要:SF6气体绝缘变压器在我国电力系统中的应用越来越广泛,建立运行中的气体分析的有效检测手段和监督依据,对此类电气设备进行监督管理显得尤其重要。为此,根据深圳供电分公司SF6变压器投运七年来的运行情况和监督检测方面所积累的经验,结合厂家的监督标准,提出了SF6变压器气体监督检测方面的建议,为SF6气体绝缘变压器的安全运行和监督提供参考。The evergrowing use of SF_(6) gas insulated transformers in China's power system necessitates effective in-service gas detecting means and monitor standards. Based on the operation situation of SF_(6) transformers in Shenzhen Power Supply Branch, the experience in their monitoring and detection as well as the manufacturer's monitor standard, suggestions on gas monitoring and detection for SF_(6) transformers are put forward, which are referable for the safe operation and monitoring of SF_(6) gas insulated transformers.

关 键 词:SF6气体绝缘变压器 气体分析 监督检测 

分 类 号:TM415[电气工程—电器]

 