含硫污水汽提装置腐蚀分析  被引量:8

ANALYSES OF CORROSION OF SULFUR-CONTAINING WASTEWATER STRIPPING UNIT

在线阅读下载全文

作  者:张仲明 李红奎 郑军 

机构地区:[1]洛阳石化分公司铁运部,洛阳471012

出  处:《腐蚀与防护》2004年第11期483-485,共3页Corrosion & Protection

摘  要:洛阳石化分公司含硫污水汽提装置腐蚀的主要部位是进料部位、塔顶分凝系统、侧线抽出的分一液相系统等。文章具体分析了以上各个部位腐蚀的原因,认为最重要的腐蚀形式是湿硫化氢应力腐蚀。指出介质的浓度、流速及溶液的pH值与上述腐蚀有关,并提出具体的防护措施。The main corroded parts of sulfur-containing wastewater stripping unit in Luoyang Petrochemical Complex/SINOPEC are inlet, top segregator and liquid phase of the first-segregator in side-off system. In this article, the reasons for corrosion of above parts are analyzed. Stress corrosion by wet H_2S is regarded as the most importment reason. It is concluded that H_2S concentration. flow-rate and pH of the mediun are closely related to the corrosion. Protective measures have been suggested for different parts.

关 键 词:含硫污水汽提装置 腐蚀 防护措施 

分 类 号:TG174[金属学及工艺—金属表面处理] TE986[金属学及工艺—金属学]

 