检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:黄新元[1] 刘长振[1] 张凯[1] 马东森[2]
机构地区:[1]山东大学,山东济南250061 [2]华能德州电厂,山东德州253024
出 处:《中国电力》2004年第11期39-42,共4页Electric Power
摘 要:建立了计算华能德州电厂2209t/h锅炉侧墙包复过热器流量偏差的数学模型,指出该炉频繁爆管的根本原因在于侧墙包复过热器存在固定的滞流区域。利用本模型对增加的管子入口节流圈的流量分布进行估计,采取相应措施后解决了该炉的爆管问题。<abstract>mathematical model for the steam flow distribution in sidewall enclosure superheater of 2 209 t/h boiler in Huaneng Dezhou power plant was established.The basic cause for the frequent tube rupture was analyzed as the presence of a stable slow flow zone on the front of sidewall enclosure superheater.The flow distribution was estimated with throttle rings added at the inlet of every tube by using this model. Corresponding measures were taken with the troubles of tube rupture eliminated.
分 类 号:TK228[动力工程及工程热物理—动力机械及工程]