检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《化肥设计》2004年第3期52-54,共3页Chemical Fertilizer Design
摘 要:分析了中压变换饱和塔改造的原因和依据 ,论述了新型垂直筛板塔的工作原理及其在中压变换饱和塔的应用改造情况 ,对改造前后运行参数和经济效益进行了分析对比。结果表明 ,改造后吨氨电耗下降 19kW·h ,吨氨蒸汽消耗下降 30 0kg ,每月可节省脱盐水 10 0 79m3 。Cause and basis for reforming the middle pressure s hi ft saturation column were analyzed,working principle of the new type of vertic al sieve plate column and its reforming situation in the middle pressure shift s aturation column were discussed,analysis and contrast were made for the operat ing parameters and economic benefit before and after reformation. Result indicat es that the power consumption /ton ammonia after reformation is 19 kW·h reduced ,steam consumption /ton ammonia is 300 kg decreased,demineralized water can be 10 079 m 3 saved monthly.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©