检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王广军
机构地区:[1]中国建筑科学研究院建筑防火研究部
出 处:《建筑科学》1993年第4期23-27,共5页Building Science
摘 要:震损多层砖房可根据其破坏程度进行修复加固,其加固水准应根据当地的设防烈度、遭遇烈度和经济状况加以确定。加固时,可按《建筑抗震设计规范》GBJ11-89的方法进行验算;其加固措施与震前加固方法相同。砖房经加固后,当遭遇下一次地震影响时,经修理或稍加修理即可使用。According to damaged degree, earthquake damaged multi-storey brick buildings can be repaired and strengthened. Strenthening level should be determined by defencing earthquake intensity, encountering earthquake intensity and economic situation of the locality. As repairing and strengthening, it should be checked on the basis of 《Code for Aseismic Design of Building Structures》 GBJ 11-89. The strengthening measures are in the same way of doing that before earthquake. When strengthening brick buildings encounter next earthquake, they will be still used after proper repairing.