二次凝聚法去除受污染原水TOC的影响因素研究  

Influencing factors on TOC removal from polluted raw water in two-stage coagulation process

在线阅读下载全文

作  者:何成达[1] 鲁梦江[2] 周春红[2] 虞林堂[2] 

机构地区:[1]河海大学环境科学与工程学院,南京210098 [2]扬州大学环境科学与工程学院,扬州225009

出  处:《给水排水》2004年第10期30-32,共3页Water & Wastewater Engineering

基  金:江苏省高校科研基金(02KJB610004)

摘  要:基于已有的研究成果通过混凝烧杯试验就二次凝聚法的凝聚剂投加量比例、快速混合强度和pH范围等因素对原水TOC去除效果的影响进行了研究。试验结果表明,将常规凝聚的加药量等分2次投加能取得最好的原水TOC去除效果,高混合强度有利于去除原水TOC,二次凝聚的最佳pH范围与原水pH范围一致。The influencing factors on TOC removal in two-stage coagulation process, including the dosage of coagulants, the mixing intensity and the pH range of the raw water are researched by means of jar test. The experimental results show that the best dosage of flocculant for normal coagulation is divided into two equal portions and added at two times. High mixing intensity is helpful for TOC removal. The best pH range at the process is accordant with that of the raw water.

关 键 词:TOC 去除效果 污染 原水 烧杯试验 混凝 快速混合 凝聚法 量比 投加 

分 类 号:TU991[建筑科学—市政工程] X703[环境科学与工程—环境工程]

 