机构地区:[1]The Key Laboratory of Analytical Science of MOE, Department of Chemistry, Xiamen University, Xiamen, Fujian 361005, China [2]Cancer Research Center of School of Life Science, Xiamen University, Xiamen, Fujian 361005, China
出 处:《Chinese Journal of Chemistry》2004年第11期1319-1324,共6页中国化学(英文版)
基 金:Project supported by the National Natural Science Foundation of China (No. 29775021).
摘 要:The fluorescence behavior of two near-infrared (NIR) chromophores with linear alkyl chains of different lengths, 2-[4'chloro-7'(3'ethyl-2'benzothiazolinylidene)-3',5'-(1''',3'''-propanediyl)-1',3',5'-heptantriene-1'-yl]-3-ethylbenzo- thiazolium iodide (Probe I) and 2-[4'chloro-7'(3'hexadecyl-2'benzothiazolinylidene)-3',5'-(1''',3'''-propanediyl)- 1',3',5'-heptantriene-1'-yl]-3-ethylbenzothiazolium iodide (Probe II), in aqueous solution containing different con-centrations of surfactants was studied. The fluorescence of the probe with a short chain (probe I) was completely quenched in water and aqueous solution containing a low concentration (below the critical micelle concentration, CMC) of surfactant Triton X-100. However, the fluorescence reappeared and reached maximum rapidly once the concentration of the surfactant approached the CMC. The probe with a long chain (probe II) displayed a similar fluorescence behavior but more dramatically fluorescent recovery in Triton X-100 system, which gave a direct in-dication for the micelle forming process and provided a simple method for the determination of the critical micelle concentration of the surfactant. The CMC values determined by this method were in good agreement with those ob-tained by other techniques. The fluorescence behavior of the two probes in other surfactant systems was also inves-tigated.The fluorescence behavior of two near-infrared (NIR) chromophores with linear alkyl chains of different lengths, 2-[4'chloro-7'(3'ethyl-2'benzothiazolinylidene)-3',5'-(1''',3'''-propanediyl)-1',3',5'-heptantriene-1'-yl]-3-ethylbenzo- thiazolium iodide (Probe I) and 2-[4'chloro-7'(3'hexadecyl-2'benzothiazolinylidene)-3',5'-(1''',3'''-propanediyl)- 1',3',5'-heptantriene-1'-yl]-3-ethylbenzothiazolium iodide (Probe II), in aqueous solution containing different con-centrations of surfactants was studied. The fluorescence of the probe with a short chain (probe I) was completely quenched in water and aqueous solution containing a low concentration (below the critical micelle concentration, CMC) of surfactant Triton X-100. However, the fluorescence reappeared and reached maximum rapidly once the concentration of the surfactant approached the CMC. The probe with a long chain (probe II) displayed a similar fluorescence behavior but more dramatically fluorescent recovery in Triton X-100 system, which gave a direct in-dication for the micelle forming process and provided a simple method for the determination of the critical micelle concentration of the surfactant. The CMC values determined by this method were in good agreement with those ob-tained by other techniques. The fluorescence behavior of the two probes in other surfactant systems was also inves-tigated.
关 键 词:Triton X-100 critical micelle concentration (CMC) near-infrared (NIR) dye FLUORIMETRY
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...