检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]水利部淮河水利委员会治淮工程建设管理局,安徽蚌埠233001
出 处:《水利水电科技进展》2004年第5期41-44,共4页Advances in Science and Technology of Water Resources
摘 要:为解决立交地涵施工期混凝土的温控防裂问题,用三维温度场和应力场有限元法对淮安某立交地涵工程混凝土结构进行施工期的仿真计算分析,对结构施工分层、设置后浇带、部分整体浇筑和多种保温等混凝土防裂措施进行了计算和比较,了解这些防裂措施的效果,进而找出最有效的防裂措施,为工程混凝土结构的施工提供科学指导.The temperature and cracking control of concrete structures during the construction period of grade-separation culverts is one of a key problems that have not been solved. In the present study,the 3-D temperature and creep stress fields of the concrete structure of a Huaian grade-separation culvert during its construction period were simulated with the finite element method. A comparative analysis was performed on some anti-cracking measures, including stratified construction, setting of successive casting belt, integral casting of some parts, and multiple measures for thermal insulation, so as to recognize the effectiveness of the anti-cracking measures, and further to find out the most suitable measures for concrete construction in the project.
关 键 词:立交地涵 混凝土裂缝 有限元 施工分层 整体浇筑 后浇带 保温措施
分 类 号:U449[建筑科学—桥梁与隧道工程] O241[交通运输工程—道路与铁道工程]