Simultaneous determination of seven impurities in high-purity cobalt oxide by ICP-AES after matrix separation using 1-nitroso-2-naphthol as a precipitant  被引量:1

Simultaneous determination of seven impurities in high-purity cobalt oxide by ICP-AES after matrix separation using 1-nitroso-2-naphthol as a precipitant

在线阅读下载全文

作  者:王艳 周春山 段青兵 陈萍 

机构地区:[1]College of Chemistry and Chemical Engineering, Central South University, Changsha 410083,China [2]Quality Inspection Center of Hexanelactam Plant, Baling Petrochemical Limited Company,Yueyang 414003, China

出  处:《Journal of Central South University of Technology》2002年第2期100-103,共4页中南工业大学学报(英文版)

摘  要:A method was developed for the simultaneous determination of seven trace impurities (Cd, Mn, Pb, Zn, Cu, Fe and Ni) in high purity cobalt oxide by ICP AES. The matrix effect was eliminated by preci pitation with 1 nitroso 2 naphthol. The matrix effect of cobalt on the absorptions of trace impurities, the effects of reaction time, pH value, dosage of precipitant on the formation of cobalt 1 nitroso 2 naphthol complex, the effects of hydrochloric acid on the stability of this complex and masking of elements were studied. Recoveries of the impurities in spiked sample are from 90% to 110% with a precision of 1.1% 5.0% RSD. The detection limits of the seven elements are in the range of 0.01 0.24μg/g. The method can be applied to the analysis of high purity cobalt metal, cobalt oxide and other cobalt compounds.A method was developed for the simultaneous determination of seven trace impurities (Cd, Mn, Pb, Zn, Cu, Fe and Ni) in high purity cobalt oxide by ICP AES. The matrix effect was eliminated by preci pitation with 1 nitroso 2 naphthol. The matrix effect of cobalt on the absorptions of trace impurities, the effects of reaction time, pH value, dosage of precipitant on the formation of cobalt 1 nitroso 2 naphthol complex, the effects of hydrochloric acid on the stability of this complex and masking of elements were studied. Recoveries of the impurities in spiked sample are from 90% to 110% with a precision of 1.1% 5.0% RSD. The detection limits of the seven elements are in the range of 0.01 0.24μg/g. The method can be applied to the analysis of high purity cobalt metal, cobalt oxide and other cobalt compounds.

关 键 词:trace impurity high  purity cobalt oxide matrix separation inductively coupled plasma atomic emission spectrometry (ICP  AES) 

分 类 号:O657.3[理学—分析化学]

 