检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:饶志明[1] 吴秋莲[1] 谢国平[1] 许环环[1] 张秀青[1]
出 处:《分析化学》2004年第12期1660-1662,共3页Chinese Journal of Analytical Chemistry
摘 要:研究在硫酸盐酸介质下,心得安(盐酸普萘洛尔)与铈和罗丹明B的化学发光行为,并对影响化学发光强度的诸因素进行实验和探讨,建立了流动注射化学发光法检测心得安的新方法。其线性范围为8.0×10-5~8.0×10-3g/L;检出限为2×10-5g/L;对1.0mg/L心得安连续11次测定的相对标准偏差为15%。该方法应用于心得安片剂含量测定并与标准方法(中国药典法)比较,结果满意。A new system for the determination of propranolol hydrochloride with flow injection chemiluminescences was described. It is based on the chemiluminescence's reaction of propranolol hydrochloride-Ce(IV)-rhodamine B in acidity medium. A method based on the enhanced chemiluminescence for propranolol hydrochloride determination has been developed. The method has high sensitivity, selectivity and good repeatability with a linear concentration range of 8.0 x 10(-5) similar to 8.0 x 10(-3) g/L propranolol hydrochloride and a detection limit of 2 x 10(-5) g/L and RSD of 1. 5 % (n =11, C-s = 1.0 mg/L).
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15