消除单桥路静止无功发生器谐波的仿真  被引量:1

The Simulation about Harmonic Elimination of Advanced Single-bridge Static VAR Generator

在线阅读下载全文

作  者:许智升[1] 陈少华[1] 程汉湘[1] 

机构地区:[1]广东工业大学自动化学院,广东广州510090

出  处:《广东工业大学学报》2004年第4期9-15,共7页Journal of Guangdong University of Technology

基  金:2002年省科技厅攻关资助项目(2002C1020103;粤财企[2002]254号)

摘  要:先进的单桥路静止无功发生器(ASVG)存在的最大问题是自身输出的电流含有很大的谐波.通过对ASVG典型负载的仿真分析,提出了改进措施,并分析了原因,得出了改进后的仿真波形,极大地减少了系统的电流电压谐波含量,证明了该方法的可行性、经济和简易.文中还阐述了ASVG的硬件构成和数学推导过程、控制系统等.The most serious problem about advanced single-bridge static VAR generator is its quantities of harmonic during PWM Through simulation of typical ASVG load,this paper puts forward a changed hardware structure and the reason is analyzedComparing the simulation picture with the pre-changed one,the probability, easiness and economy are seen for the changeThe hardware structure, mathematics model and control principle are also described in this paper

关 键 词:先进静止无功发生器 谐波 有源滤波 

分 类 号:TM761[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象