铝硒共沉淀体系除硒影响因素研究  被引量:7

Study on Factors of Removing Selenium by Using Aluminum-Selenium Co-Precipitation System

在线阅读下载全文

作  者:王琳[1] 徐冰峰[1] 张梅[1] 施永生[1] 

机构地区:[1]昆明理工大学建筑工程学院,云南昆明650224

出  处:《昆明理工大学学报(理工版)》2004年第6期104-107,共4页Journal of Kunming University of Science and Technology(Natural Science Edition)

基  金:云南省自然科学基金资助项目 (项目编号 :2 0 0 1E0 0 2 0M)

摘  要:就铝硒共沉淀体系除硒影响因素进行研究 ,探讨确定含硒原水处理工程的设计参数和运行控制条件 .结果表明 ,AlCl3投加量在 40mg/L即可 ,搅拌时间在 5~ 1 0min之间为宜 ,最佳pH值则在 6.5~ 7.5之间 。Aimed at finding the design parameter and running data of removal selenium from raw water, studies were made on the effects of the treatment process by using aluminum-selenium co-precipitation system. The findings show that good effect of selenium removal can be achieved when dosage of AlCl 3 is 40 mg/L at pH of 6.5~7.5 with the mixing time of 5~10 min. Moreover, the proper scopes of turbidity and temperature of raw water are wider when this effect is achieved.

关 键 词:  除硒 共沉淀  影响因素 