机构地区:[1]清华大学化学系,北京100084 [2]漳州师范学院化学系,漳州363000
出 处:《高等学校化学学报》2005年第1期49-51,共3页Chemical Journal of Chinese Universities
基 金:国家自然科学基金 (批准号 :2 0 175 0 11);福建省自然科学基金 (批准号 :C0 110 0 2 8)资助
摘 要:Room temperature phosphorescence(RTP) signal intensity of eosin-ITC on a polyamide membrane(PM) was very low, but the signal was increased obviously once some inorganic salts were added into the system at λ ex/λ em=532 nm/685 nm. The enhancement effect of ⅡA element ions(such as Ca 2+, Sr 2+ and Ba 2+) on RTP of eosin-ITC is much obvious than that of Pb 2+ and Hg 2+ used constantly as an outer heavy atom perturber in phosphorimetry. Based on that, a new solid substrate room temperature phosphorescence immunoassay(SS-RTP-IA) for the determination of the human IgG was proposed to demonstrate the feasibility using eosin-ITC as phosphorescent marker. It was found that a good linear relationship with the ΔI P was obtained when the amount of human IgG in the range from 6.25 to 400 pg/spot(corresponding to the mass concentration: 15.63 ng/mL—1 μg/L, sample volume of 0.4 μL/spot). The regression {equation} of working curve can be expressed as ΔI p=3.062+0.00864x(pg)(n=7, r=0.996), The detection limit calculated as 3S b/k is 0.394 pg/spot. The method was applied directly to the determination of IgG in human serum with a satisfying result. These results show that eosin-ITC can be used conveniently as a RTP marker of high sensitivity.Room temperature phosphorescence(RTP) signal intensity of eosin-ITC on a polyamide membrane(PM) was very low, but the signal was increased obviously once some inorganic salts were added into the system at λ ex/λ em=532 nm/685 nm. The enhancement effect of ⅡA element ions(such as Ca 2+, Sr 2+ and Ba 2+) on RTP of eosin-ITC is much obvious than that of Pb 2+ and Hg 2+ used constantly as an outer heavy atom perturber in phosphorimetry. Based on that, a new solid substrate room temperature phosphorescence immunoassay(SS-RTP-IA) for the determination of the human IgG was proposed to demonstrate the feasibility using eosin-ITC as phosphorescent marker. It was found that a good linear relationship with the ΔI P was obtained when the amount of human IgG in the range from 6.25 to 400 pg/spot(corresponding to the mass concentration: 15.63 ng/mL—1 μg/L, sample volume of 0.4 μL/spot). The regression {equation} of working curve can be expressed as ΔI p=3.062+0.00864x(pg)(n=7, r=0.996), The detection limit calculated as 3S b/k is 0.394 pg/spot. The method was applied directly to the determination of IgG in human serum with a satisfying result. These results show that eosin-ITC can be used conveniently as a RTP marker of high sensitivity.
关 键 词:固体基质室温磷光免疫分析法 异硫氰酸曙红 CaCl2作增强剂 人IGG
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...