开窗对金属板屏蔽小室稳态屏蔽效能影响的对比测试  被引量:4

Shielding Effectiveness Contrast Test of Metal Plate Shielding Cabin with Windows

在线阅读下载全文

作  者:梁晓兵[1] 高新华[1] 饶章权[2] 余军[2] 王建国[2] 周文俊[2] 张磊[2] 

机构地区:[1]广东省电力试验研究所,广州510600 [2]武汉大学电气工程学院,武汉430072

出  处:《电测与仪表》2005年第2期53-56,共4页Electrical Measurement & Instrumentation

摘  要:通过对同一金属板屏蔽小室的三个不同门窗屏蔽效能的测试,得到了三个不同门窗的屏蔽小室在0.03kHz~10kHz和10kHz~1000kHz频带内的稳态屏蔽效能,结果表明虽然开窗后全钢板屏蔽小室的屏蔽效能会在局部区段有所下降,但带金属丝网玻璃窗的金属板屏蔽室也具有较高的屏蔽效能。Shielding effectiveness test of metal plate shielding cabin with three different doors in the frequency band from 0.03 kHz to 10 kHz and 10 kHz to 1000 kHz has been conducted. The results show that the shielding effectiveness of metal plate shielding cabin with silk screen window could also reach to high value though the window could lead to the fall of shielding effectiveness in part frequency band.

关 键 词:电磁屏蔽 屏蔽效能 屏蔽室 

分 类 号:TN973.3[电子电信—信号与信息处理]

 