全金属孔板叠层换热器流动阻力的测试  被引量:1

Measurement of Flow Resistance of a Completely Metallic Perforated Plate Heat Exchanger

在线阅读下载全文

作  者:朱庭英[1] 龚领会[1] 郭廷玮[1] 刘刚[1] 苏福泽 

机构地区:[1]中国科学院低温技术实验中心

出  处:《低温工程》1994年第4期26-30,共5页Cryogenics

摘  要:全金属孔板叠层换热器是由铜制孔板和不锈钢隔片相间叠置,采用扩散焊工艺焊接而成。该换热器横断面为长方形,采用指型流道。作者对三个样品进行了室温下的流动阻力测试,得出了摩擦因子随雷诺数变化的关系曲线,并用最小二乘法整理成摩擦因子计算公式。The complete metallic perforated plate heat exchanger is made of a lot of perforated copper plates alternated with stainless steel spacers,and piled up and welded each other.It has rectangle cross seetions formed two finger-shaped flow passages for the high pressure gas and the low pre-ssure gas respectively。In this paper the flow resistances of three samples have been tested at room temperature。The friction factor criterion equati-ons have been given for two kinds of the perforated plate arrangements.

关 键 词:热交换器 孔板 流动阻力 测量 

分 类 号:TB657.5[一般工业技术—制冷工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象