检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:朱兴华[1] 施德广 尼新兴[1] 白凤德[2] 李福[2]
机构地区:[1]吉林工业大学 [2]白求恩医科大学
出 处:《生物医学工程学杂志》1989年第2期97-101,共5页Journal of Biomedical Engineering
摘 要:本文重点论证了槽形对向加压钢板设计的生物力学原理,介绍了与北京产矩形截面等厚度板、矩形截面变厚板即梯形板对比试验结果。A new trough opposite compression plate(TOCT)was developed and compared with the Beijing compression plate(BCP) and the trapezoid compression plate (TCP).The cross section of TOCP is trough-shaped, thus the bending strength and rigidity of TOCP was greatly increased. The bending strength of TOCP is 2. 74 times and the bending rigidity is 6.6 times as much as that of BCP which has the same width and thickness.With TOCP the area of bone under pressure was reduced by 70%, compared with that of rectangular section plate.The TOCP has three-area fixation and is much more effective on preventing nail dislocation. The TOCP has opposite compression and is better able to prevent fracture face detachment.As shown, TOCP is beneficial to bone healing.The results of four-point bending test show that bending strength of fixed TOCP is 3.95 times that of fixed BCT and is 1.3 times that of fixed TCP. Bending rigidity of fixed TOCP is 5 times that of fixed BCP and is 2.5 times that of fixed TCP.
分 类 号:R318.01[医药卫生—生物医学工程]