摘 要:建立了测定麻疹病毒抗体的酶免疫电化学分析法。其原理是在异相酶联免疫之后用极谱法检测酶促产物。本法采用小型三电极系统“DME-Pt-Ag/AgCl”直接与商品酶联板配套使用,简化了操作步骤。对测定麻疹抗体的合适条件以及灵敏度,特异性等作了考察。结果表明,本法特异性强,灵敏度高,检测范围宽,不受样品颜色、浊度、杂散光及酶联板自身光吸收不均一的影响;应用于测定三批共118份血清样品,阳性率分别为15%(6/40),62.5%(25/40)和31.58%(12/38),用46份样品对本法和ELISA作相关性检验,其相关性良好(γ=0.77.t_r=10.84,P<0.001,相关显著)。An electrochemical enzyme immunoassay for measles virus(MV) was based on heterogeneous enzyme immunoassay with polarographic detection. The measurement of the enzyme-catalyzed product is carried out directly in commercial microporous plate by linear-sweep polarography with a small three electrode system 'DME-Pt-Ag/AgCl'.The positive ratio determined by the proposed method in 118 sera specimens is higher than that by ELISA,and the good relativity of the proposed method wite RLISA(γ=0.77, tr=10.84,P<0.001)was observed by measuring 46 specimens.The proposed method bas high specificity, sensitivity, wide detection range,without the interferences of turbidity colour of samples,stray light and adsorption inhomogenity of micro-porous plate.