催化荧光法测定痕量锰的研究  被引量:11

Study on Catalytic Fluorescence Method for Deter-mination of Trace Manganese

在线阅读下载全文

作  者:陈亚华[1] 韩秀丽[1] 

机构地区:[1]郑州大学化学系,郑州磨料磨具磨削研究所

出  处:《分析试验室》1994年第1期40-42,共3页Chinese Journal of Analysis Laboratory

摘  要:本文基于在弱酸性介质中及活化剂氨三乙醚存在下,锰(Ⅱ)对高碘酸钾氧化meso-四(4-三甲铵苯基)卟啉的催化作用,提出了一个测定痕量锰的催化荧光新体系。方法的检出限为8.1×10 ̄(-2)ng/mL,线性范围为10~40ng/25mL,1~10ng/25mL,不经分离可直接用于精镁中锰的测定。new catalvtic fluorescence method has been de-scri bed for the determination of trace manganese,It is based on the catalysis of Mn(Ⅱ)to oxidizl meso-tetrakis-(4-trimethylam monium phenyl)-porphyrin with potass-ium periodate and nitrilo triacetic acid as activator in HAc-NaAc buffer solution(pH4.5).The detection limit for Mn is 8.1×10 ̄(-2)ng/mL.The linear range of deter-mination is 10~40ng/25mL,1~ 10ng/25mL of Mn.The method has been used to determine trace Mn in pure magnesium.

关 键 词: T(4-TAP)P 催化荧光法 显色剂 

分 类 号:O614.711[理学—无机化学]

 