作  者:林文业[1] 何聿忠[1] 罗建慧[1] 林葵[1] 黄丽娟[1] 黄文绮 磨传真[1] 吴开国[1] 

机构地区:[1]广西分析测试研究中心,广西医学院

出  处:《光谱学与光谱分析》1994年第3期93-96,共4页Spectroscopy and Spectral Analysis

摘  要:本文采用偏振塞曼原子吸收法,血液基体匹配标准,以Ca作基体改进剂直接测定人体全血中痕量硅,既降低了硅原子化温度又提高了硅的测定灵敏度,克服了血液基体的干扰。方法的相对标准偏差小于5.0%,回收率在95.8~106%之间。in this paper, the content of silicon in blood of human body is directly measuredby Z-7000 polarized zeeman AAS. This paper studies a seletive test of ashing and atomizingtemperature and interference factors with calcium matrix improver and graphite tube withwolfram-coated and the standard solution matched with blood matrix. The result is foundthat this method not only reduces silicon's atomizing temperature, but also improves itssensitivity and avoids the interference of blood matrix. The RSD is less than 5. 0%. The recovery is from 95. 8% to 106%.

关 键 词:血液  原子吸收光谱 

分 类 号:Q592.1[生物学—生物化学]

 