使用臭氧消毒器对室内空气的污染  被引量:11

The Pollution of Ozone Disinfection Apparatus on Indoor Air

在线阅读下载全文

作  者:王沭沂[1] 王克波[1] 方企圣[1] 

机构地区:[1]南京医学院环境医学研究室

出  处:《环境与健康杂志》1994年第1期22-23,共2页Journal of Environment and Health

摘  要:本文研究了目前常用的臭氧(O3)消毒器(O3消毒箱和O3空气消毒净化器)对室内空气所造成的影响。在容积60m3的测试室中,消毒器按常规方式工作,用硼酸碘化钾比色法和化学发光分析仪测定室内O3浓度。结果表明O3消毒箱和O3空气消毒净化器在工作时产生的O3已造成室内空气的污染,并超过标准规定。笔者认为,O3是一种有害气体,应在O3消毒器的生产和使用中做好防护工作。This paper examined the pollution in indoor air during utilization of disinfection apparatus(ozone disinfector and ozone air sterilize-cleaner).Ozone concentrations were determined by boric acid-potiassium iodide colorimetric method and chemiluminescence method in a test chamber(volume 60m3)under the normally opration of ozone disinfection apparatus. The result showed that the highly toxic gas-ozone concentrations in test chamber have surpassed the limit value of air standard. Therefore it is recommended that one should pay attention to protection of the ozone pollution when the ozone emitting apparatus is producted and used.

关 键 词:臭氧 消毒器 室内空气污染 

分 类 号:R126.8[医药卫生—环境卫生学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象