ICP-AES法测定矿渣中痕量金  被引量:1

Determination of trace gold in slag by ICP-AES method

在线阅读下载全文

作  者:刘虎生[1] 李林荣[1] 

机构地区:[1]核工业北京化工冶金研究院

出  处:《黄金》1994年第2期50-52,共3页Gold

摘  要:ICP-AES法测定矿渣中痕量金。称样5.0000g于650℃灼烧后,用王水溶解,滤液通过TBP萃取树脂色谱柱吸附,0.1mol/LHCl+0.1mol/L硫脲混合淋洗液解脱。本法分析0.051g/t含量的金标样,结果与推荐值吻合。六次分析结果的相对标准偏差(RSD)<5%。回收率为96%~104%。方法简便,快速和准确。Taking 5.0000 g of sample to be scorched,then,dissolve the scorched sample with aqua regia followed by filtration.The trace gold in the filter liquor are adsorbed in the chromatographic column containing TBP extracting resin and the adsorbed gold are eluted by the mixed solution of 0.1 mol/L HCI and 0.1 mol/L thiourea. Result of analysing sample of 0.051 g/t gold content coincides with the acknowledged value. Relative standard deviations of the six time's analysing results are less than 5% and the recovery rates are 96%-100%. This method is simple, speedy and accurate.

关 键 词:矿渣 ICP-AES  痕量分析 

分 类 号:TF801.3[冶金工程—有色金属冶金]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象