药敏药片对临床235株细菌实验观察报告  被引量:1

The Report of Experimental Observation on Sensitabs to Clinical 295 Strans of Bacteria

在线阅读下载全文

作  者:路娟[1] 闫玉[1] 陈非[1] 于阿元 敬德仲 李新玉[1] 王淑华[1] 曲杰[1] 邹碧珍[1] 韩美丽[1] 

机构地区:[1]哈尔滨医科大学第一医院微生科,黑龙江省医院实验诊断部,哈尔滨市第一医院临床检验中心,哈尔滨市红十字儿童医院检验科,黑龙江省科学院应用微生物研究所

出  处:《生物技术》1994年第5期34-37,共4页Biotechnology

摘  要:药敏药片经临床对金黄色葡萄球菌、大肠埃希氏菌、铜绿假单胞菌等235株考核.表明药片工艺研究先进,药片与培养基结合牢固,无断裂、崩解,不渗出颗粒,抑菌圈呈同心园扩散.边缘清楚。药物含量均匀,释放度好。药片抑菌差仅1~3mm;而纸片抑菌差为2~12mm。药片变黑系数CV为2.71~4.21;而纸片CV为3.82~14.36。表明纸片片间差大,药片精密度明显好于纸片。The Sensitabs of feet on clinical 235 Strains of bacteria such as staphytoceccus aureus. Escherichia Coli and Pseudomonas aeruginosa have been examined, it shown that the workmanship of producing sensitabe is perfect; The combination of between sensitabs and medal is strong; There is not break up in it and Particles out of it; The inhibition zones of bacteria is a homocentric spread cycles, edges of it is clear.The content of drugs is homogenous; Release rate of drugs is good.The difference of the diameters between inhibition zone of the sensitabe is 1mm-3mm,but the defference between paper's discs is 2mm-12mm, The variation coeffecient of giblets CV is 2. 71-4. 21, That of paper discs CV is 3. 82 -14. 36. Therefore the results shown that there is a big difference between the diameters of paper discs, then there is a better precision of tablets than paper discs.

关 键 词:药敏试验 药敏药片 纸片 细菌 

分 类 号:R446.5[医药卫生—诊断学]

 