检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]武汉大学,武汉市430072 [2]武汉高压研究所,武汉市430074
出 处:《电力建设》2005年第3期51-53,共3页Electric Power Construction
摘 要:随着配电网规模的不断扩大,种类繁杂的自动补偿消弧装置的并联运行问题凸现。从消弧线圈的调谐方 式和运行情况来看,可采用3种并联运行方式,即自动并联方式、主从并联方式和集中控制方式。三者各有其优缺点, 用户应根据实际情况,从运行的场合、消弧线圈种类、通讯等方面综合考虑,因地制宜地选择适用的并联运行方式。With continuous expansion of distribution power network the problem of parallel operation of automatic compensation arc suppression device becomes more serious. From view point of tuning mode and operation for the arc suppression coil there are 3 kinds of parallel operation modes, including automatic parallel, primary and secondary parallel and concentrated control. These 3 kinds have their individual advantages and disadvantages. The customers should consider in general according to the actual conditions, operation environment, type of arc suppression coil, communication and so on to properly select the suitable parallel operation mode.