振动法在线检测电力变压器有载调压开关触头状况的可行性研究  被引量:9

Feasibility Study Using Vibration Measurement to On-line Detect the Contact Condition of OLTC

在线阅读下载全文

作  者:程锦[1] 王正刚[2] 徐燕飞[1] 李梅[1] 汲胜昌[1] 李彦明[1] 

机构地区:[1]西安交通大学电气工程学院,陕西西安710049 [2]郑州电业局,河南郑州450006

出  处:《高压电器》2005年第2期95-97,共3页High Voltage Apparatus

摘  要:以一台SYJZZ型有载调压开关为研究对象,分析振动信号与OLTC的触头状况之间的关系。首先分析了OLTC动作过程与振动信号在时间上的对应关系,提取出正常信号的基本特征,并找出与故障信号的区别,进而分析故障信号的原因。比较振动信号的分析结果与实际故障的检测结果,得出振动法检测变压器有载调压开关是一种有效可行的方法。In this paper, an on-load tap-changer, of type of SYJZZ, was studied. The correlations between vibration signal and contact condition were analyzed to extract the traits of normal signal, and get the discrepancies of fault signal and normal signal, eventually analyze the causes of fault signal. By verifying the results derived from vibration signal analysis, it is concluded that vibration method is an effective and practical way to assess the contact condition of OLTC.

关 键 词:有载调压开关 振动信号 触头 

分 类 号:TM41[电气工程—电器]

 