摘 要:以国产石英光纤作光路、硫化铅探测器为敏感元件所构成的中温光纤辐射测温仪,在200℃以上实现了1℃分辨力的温度检测;以氟化物光纤作光路、硒化铅探测器为敏感元件,初步实验结果是80℃以上获得了1℃的分辨力。提出一种新的桥路双平衡调解法,较好地解决了半导体探测器的温漂问题。系统所采用的积分与累加检测法对噪声与干扰有明显的抑制作用。A moderate temperature fiber optic pyrorneter using a silica fiber as light transmission and a PbS detector as photosensing is developed to detect temperature above 200℃ with a resolution of 1℃, Utilizing a fluoride fiber and a PbSe detector,a primary experiment shows that a resolution of 1℃ can be ob-tained above 80℃. A new method called double ballance bridge is introduced,which solves the problem of the ternperature drift of semiconductor detectors very well.The noise and interference are reduced significantly by a combination of integration and accumulation detective methods.