摘  要:在研究动态主动调焦法测量原理的基础上,提出一种新型的动态主动调焦式激光测头的检测方法。该检测方法的核心原理是将位移量的测量转换成了时间差的测量,从而简化了激光测头的结构,提高了激光测头的测量精度和稳定性。介绍了所设计的高精度激光测头测量系统,并对激光测头进行了动态特性的实验。结果表明激光测头的测量分辨力为0 .075μm,测量线性度为0. 45μm,测量范围为±0 .1 mm。Based on a study optical dynamic active co nf ocal probe, a new method of the measuring deviation focus is developed. The key point of this new method is that displacement of the turning fork is converted t o time difference measurement, thus the optical and mechanical structures of the laser probe system can be simplified greatly, and its accuracy and stabilit y are enhanced. A new high integration measurement system is designed, and syste matic experiments resulted of the including linearity, measuring range and perfo rmance were carried out.