检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:汪丽[1] 田维坚[1] 王耀祥[1] 屈有山[1]
机构地区:[1]中国科学院西安光学精密机械研究所光纤与集成光学研究室
出 处:《光子学报》2005年第4期613-615,共3页Acta Photonica Sinica
基 金:国家 863计划基金资助项目
摘 要:采用直接对倾斜刀口成像的方法测量光锥与CCD耦合器件的调制传递函数 这种方法对静止刀口成像,利用刀口与光锥纤维列间的一定倾斜角度,在垂直于刀口的不同行之间形成不同的值,代替了传统刀口扫描中的扫描装置,并无需保证刀口与阵列的平行,相应地减小了测量误差在数据处理中采用了二次平均法,即对同一幅图像得出的不同位置值进行平均及多次测量结果平均。A method that imaged directly to sloping edge was used to get the modulation transfer function of fiber optic taper coupled with CCD. It used static edge that was tilted slightly with respect to the columns of fibre to achieve different value of different row. This method replaced scanning in conventional test and it was not necessary to ensure that edge was parallel strictly to array. Thus mechanical error was deduced accordingly. In data processing adopting two averages including different position of one image and multi-measurement result. This processing avoided the influence of non-isoplanantic result from dispersancy to a certain extent.