机构地区:[1]首都师范大学资源环境与旅游学院光断代实验室,三维信息获取与应用教育部重点实验室,资源环境与GIS北京市重点实验室,北京100037
出 处:《核技术》2005年第5期391-394,共4页Nuclear Techniques
基 金:北京市自然科学基金(8002006)北京市教委科技发展计划北京市优秀人才基金资助项目
摘 要:对一个多矿物样品在BG2003释光谱仪上获得了包括红光、绿光和热释光的选频释光特征图谱,并求得样品不同激发方式下的等效剂量值和饱和剂量值,明确了不同激发方式下样品的不同波长可适用于年龄测定。同时与在热释光仪RGD-3B上求得的等效剂量值和饱和剂量进行了对比,两个饱和剂量值有很好的一致性(均为400Gy)。We have acquired characteristic spectra of a sample consisting of many minerals for the selected frequency luminescence using BG2003 spectronmeter stimulated with red light, green light of a laser source, and a heat source, respectively. And its DE and saturated dose can be obtained under different stimulation conditions. It is clear that different wavelengths can be adopted for dating. The saturated dose measured using BG2003 spectrometer was consistent with that measured using RGD-3D TL equipment, which was equal to 400 Gy.