机构地区:[1]上海交通大学机械与动力学院核科学与系统工程系,上海200030
出 处:《原子能科学技术》2005年第3期240-245,共6页Atomic Energy Science and Technology
摘 要:核电站数值反应堆系统(DRS)是基于轻水反应堆瞬态系统分析程序RELAP5的工程模拟器。本工作使用该工具模拟恰希玛(CHASHMA)核电站蒸汽发生器传热管破裂(SGTR)事故,对30min不干预和30min内干预分别进行计算。仿真过程及计算结果验证了数值反应堆系统是进行核电厂仿真和分析的有效工具。The postulated accident of steam generator tubes rupture (SGTR) of CHASHMA nuclear power plant in Pakistan was simulated and analyzed by an engineering simulator, digital reactor system (DRS) which was based on thermal hydraulic system code RELAP5. Two cases of the accident were simulated by the DRS. One was all actions which were executed by auto control system in 30 minutes, and the other was actions which were taken by operator to mitigate the accident result in 30 minutes. The accident simulation and the results prove that the DRS is very useful for the nuclear power plant simulation and safety analysis.
关 键 词:工程模拟器 核电站 仿真分析 事故 反应堆系统 RELAP5 轻水反应堆 蒸汽发生器 分析程序 有效工具 计算结果 仿真过程 传热管 核电厂 数值 干预
分 类 号:TL364.4[核科学技术—核技术及应用]