The effect of pitch and collimation on radiation dose in spiral CT  

The effect of pitch and collimation on radiation dose in spiral CT

在线阅读下载全文

作  者:CHENGQi-Jun TSANGCheung FENGDing-Hua 

机构地区:[1]SchoolofRadiationMedicineandPublicHealth,SoochowUniversity,Suzhou215006,China [2]DepartmentofPhysicsandMaterialsScience,CityUniversityofHongKong,HongKong.China

出  处:《Nuclear Science and Techniques》2005年第3期156-159,共4页核技术(英文)

摘  要:Measurements of radiation dose to patients in spiral computed tomography (CT) were completed for various collimations,table speeds and pitch. A standard CT head dosimetry phantom and thermoluminescent dosime- ters (TLD) were used for the measurement. The effect of collimation and pitch on radiation dose was studied. The results indicated that the radiation dose at the given tube current,voltage and rotation speed was inversely propor- tional to pitch. And the increasing times of dose were as decreasing times of pitch. This regular pattern was tenable for radiation dose at both central holes and peripheral holes of the phantom at pitch = 1,>1 and <1. The collimation had no impact on the radiation dose. The results also indicated that radiation dose at central holes was nearly equal to that at peripheral holes. There was no significant difference between them statistically. The study demonstrates that the pitch in spiral CT scans is the primary parameter and has significant impact on radiation dose.Measurements of radiation dose to patients in spiral computed tomography (CT) were completed for various collimations,table speeds and pitch. A standard CT head dosimetry phantom and thermoluminescent dosime- ters (TLD) were used for the measurement. The effect of collimation and pitch on radiation dose was studied. The results indicated that the radiation dose at the given tube current,voltage and rotation speed was inversely propor- tional to pitch. And the increasing times of dose were as decreasing times of pitch. This regular pattern was tenable for radiation dose at both central holes and peripheral holes of the phantom at pitch = 1,>1 and <1. The collimation had no impact on the radiation dose. The results also indicated that radiation dose at central holes was nearly equal to that at peripheral holes. There was no significant difference between them statistically. The study demonstrates that the pitch in spiral CT scans is the primary parameter and has significant impact on radiation dose.

关 键 词:辐射剂量 CT放射量测定 头部幻影 瞄准方法 

分 类 号:R814.42[医药卫生—影像医学与核医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象