作 者:CHENGQi-Jun TSANGCheung FENGDing-Hua
机构地区:[1]SchoolofRadiationMedicineandPublicHealth,SoochowUniversity,Suzhou215006,China [2]DepartmentofPhysicsandMaterialsScience,CityUniversityofHongKong,HongKong.China
出 处:《Nuclear Science and Techniques》2005年第3期156-159,共4页核技术(英文)
摘 要:Measurements of radiation dose to patients in spiral computed tomography (CT) were completed for various collimations,table speeds and pitch. A standard CT head dosimetry phantom and thermoluminescent dosime- ters (TLD) were used for the measurement. The effect of collimation and pitch on radiation dose was studied. The results indicated that the radiation dose at the given tube current,voltage and rotation speed was inversely propor- tional to pitch. And the increasing times of dose were as decreasing times of pitch. This regular pattern was tenable for radiation dose at both central holes and peripheral holes of the phantom at pitch = 1,>1 and <1. The collimation had no impact on the radiation dose. The results also indicated that radiation dose at central holes was nearly equal to that at peripheral holes. There was no significant difference between them statistically. The study demonstrates that the pitch in spiral CT scans is the primary parameter and has significant impact on radiation dose.Measurements of radiation dose to patients in spiral computed tomography (CT) were completed for various collimations,table speeds and pitch. A standard CT head dosimetry phantom and thermoluminescent dosime- ters (TLD) were used for the measurement. The effect of collimation and pitch on radiation dose was studied. The results indicated that the radiation dose at the given tube current,voltage and rotation speed was inversely propor- tional to pitch. And the increasing times of dose were as decreasing times of pitch. This regular pattern was tenable for radiation dose at both central holes and peripheral holes of the phantom at pitch = 1,>1 and <1. The collimation had no impact on the radiation dose. The results also indicated that radiation dose at central holes was nearly equal to that at peripheral holes. There was no significant difference between them statistically. The study demonstrates that the pitch in spiral CT scans is the primary parameter and has significant impact on radiation dose.
分 类 号:R814.42[医药卫生—影像医学与核医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222