三峡水电站ALSTOM机组低水头运行稳定性分析  被引量:5

Research on the low-head operation stability of left-bank ALSTOM generator units of Three Gorges Hydropower Plant

在线阅读下载全文

作  者:薛福文 万鹏[2] 熊浩 王海[2] 郑莉媛[2] 

机构地区:[1]三峡水力发电厂,湖北宜昌443133 [2]华中科技大学,湖北武汉430074

出  处:《水力发电》2005年第4期76-78,共3页Water Power

摘  要:混流式水轮机的水力稳定性与机组水力工况密切相关。以三峡电站左岸6号机组稳定性试验为例,分析了ALSTOM机组的低水头运行稳定性。根据试验分析结果,可将机组运行工况划分为小负荷区、涡带振动区、大负荷运行区。小负荷区机组效率较低,机组不宜在此区间运行;大负荷区机组运行稳定性最佳,但机组应避开强涡带工况区和特殊频率振动区运行。The operating points have direct impact on the hydraulic stability of Francis turbine. This paper presents the stability testing on left-bank No.6 generator unit of Three Gorges Hydropower Plant, under various operation points such as: part load, vortex zone load, full load. It also analyzes the vibration of special frequency. Based on the test data and its analysis, it makes some instructions and suggestions for improving the operation stability of hydro-generator units.

关 键 词:ALSTOM机组 低水头运行 稳定性 振动 涡带 三峡水电站 

分 类 号:TM623.7[电气工程—电力系统及自动化]

 