摘  要:利用离子色谱法测定尿液中的草酸根、钙、镁离子。测定草酸根时,先在尿液中加入氯化钙使之转化成草酸钙沉淀,分离后用盐酸溶解草酸钙沉淀,然后进行测定。测定钙、镁离子时,在酸性尿液中加入氧化剂过硫酸钾,在微沸状态下氧化尿液中的有机物,从而避免对色谱柱的污染。草酸根、钙、镁离子的回收率分别为108.3%~109.7%、94.9%~100.7%、97.2%~97.4%,相对标准偏差分别为2.4%、2.5%、3.1%。The determination of C_ 2O_4 2-, Ca 2+, Mg 2+ in urine was achieved by ion chromatography. Before C_ 2O_4 2- was determined, calcium chloride was added into the urine sample to form the deposit of calcium oxalate, which dissolved in HCl to make the sample solution. K_ 2S_ 2O_ 8 was used to remove the organic compounds which might pollute the column when Ca 2+ and Mg 2+ were determined. The recoveries of C_2O_4 2-, Ca 2+, Mg 2+ were 108.3%~109.7%, 94.9%~100.7%, 97.2%~97.4% respectively, and the relative standard deviation were 2.4%, 2.5%, 3.1% respectively.