摘  要:通过工程实例讨论了人工快速渗滤系统(CRI)的工艺过程和处理效果,结果除总磷外,处理生活污水其出水CODCr为5. 0~2 6 . 0mg L ,SS为1 .7~10. 0mg L ,NH3 N为0 . 30~2 .31mg L ;处理受污染的河流水时,其出水CODCr为8. 0~2 6 . 0mg L ,BOD5为1. 0~6 . 0mg L ,SS为2. 0~6 .0mg L ,NH3 N为0 . 17~2. 5 4mg L ,均能达到相应的处理要求,是值得推广的一项新型处理工艺。Combining project, this paper introduced the technology process and treatment effect of constructed rapid infiltration (CRI) system.The results indicated that except T-P CRI system had good treatment effect.When it treated domestic sewage,COD_ Cr was 5.0~ 26.0 mg/L, SS was 1.7~10.0 mg/L,NH_3-N was 0.30~2.31 mg/L.When it treated river sewage, COD_ Cr was 8.0~26.0 mg/L,BOD_5 was 1.0~ 6.0 mg/L, SS was 2.0~6.0 mg/L,NH_3-N was 0.17~2.54 mg/L.CRI system is worth popularizing as a new type of treating technology.

关 键 词:人工快速渗滤系统 CRI 工艺过程 处理效果 出水水质 污水土地处理 