从统计数据看高压电容装置接线方式的选序  被引量:3

Selected Sequence of High Voltage Capacitor Installation Connection Ways from Statistical Data

在线阅读下载全文

作  者:杨昌兴[1] 赵启承[2] 王敏[3] 华水荣 

机构地区:[1]苏杭电气科学研究所,江苏吴江215228 [2]浙江省电力试验研究所,杭州3100143 [3]浙江省电力公司,杭州310007

出  处:《电力电容器》2005年第2期9-13,27,共6页Power Capacitors

摘  要:通过对近四年国内主要生产厂家提供的10kV、35kV高压并联电容器装置的单组容量、组数和接线方式(采用的不平衡保护方式)等数据资料进行统计分析,得出装置电压等级、容量和接线方式三者关系的变化趋势,以及接线方式的选用顺序,可供工程设计参考。Through analyzing the statistical data of the single group capacity, the number of group and the pattern of unbalance protection of the high voltage shunt capacitor banks in 10kV and 35kV system, which are supplied by the main domestic manufactories in recent 4 years, the change tendency of relations of the voltage level of the bank, the capacity and the pattern of unbalance protection is presented. And the selected sequence of connection ways is also introduced. It can be referred as engineering design.

关 键 词:高压并联电容器 装置 接线方式 继电保护 

分 类 号:TM531.4[电气工程—电器] TM51

 