低密度水泥对CBL/VDL评价固井质量影响  被引量:4

Effect of low density Cementing on evaluating Cementing Quality with CBL/VDL

在线阅读下载全文

作  者:田鑫[1] 章成广[1] 李维彦[1] 

机构地区:[1]长江大学地球物理与石油资源学院

出  处:《内蒙古石油化工》2005年第6期113-114,共2页Inner Mongolia Petrochemical Industry

基  金:湖北省自然科学基金项目(项目编号:2004ABA043)

摘  要:经过室内试验,数值模拟出了不同密度水泥套管井常见4种水泥胶结情况下,声波全波波形。通过波形对比分析了水泥密度对CBL/VDL评价固井质量的影响。分析结果表明,低密度水泥对一界面套管波幅度有较大影响,对二界面套管波幅度影响不大可以忽略,因此主要影响固井质量一界面的评价。针对此种情况,本文提出了合理的建议,在低密度固井质量评价中取得了较好的效果。By test in the room, studying the whole sound wave form under the common 4 kinds of cementing glued situation in Cased wells under the condition of different density cement with the numerical simulation. By comparing low density cementing wave form with high density cementing wave form. Analysing cement density how to influence evaluate cementing quality with CBL/VDL. Analysis results indicate that low density cement have heavy influence to one interface Cased wave range. But have little effect on two interface Cased wave range .So low density cementing only influence on evaluating two interface. In this situation we put forward reasonable suggestion in this paper .Have made better result in low density cementing evaluation.

关 键 词:低密度水泥 VDL CBL 质量影响 固井质量 室内试验 水泥胶结 不同密度 数值模拟 全波波形 对比分析 分析结果 质量评价 套管波 套管井 界面 幅度 