摘 要:86例患者在食道心房起搏中度量改良中指同身寸乘以11倍为导管电极长度与其缩短和延长1cm起搏阈值的比较有非常显著差异,其起搏阈值低,不适反应轻,食道P波显示满意,一次到位,可减轻患者痛苦。在诊治心律失常,抢救室内、外患者和手术监护中有方便实用、迅速可靠、价廉等优点。The length of lead electrode which was eleven times the length of modified digitus medius proportional unit used for intra-esophageal atrial pacing on 86 patients was compared with the length lcm more or less than the lead length itself showed very significant difference in pacing threshold,which was low,adverse reaction was mild,the intra-esophageal P wave display was satisfactory.It could alleviate the patient's pain,and was easy to manipulate,practical,rapid and inexpensive in diagnosis and treatment of arrhythmia,rescuing indoor or outdoor emergency cases as well as monitoring operation.