自动洗片机定影液配制及性能测定  

The Compounding Method and Charecteristical Test of Fixer Solution for Automatic Processor

在线阅读下载全文

作  者:程相晨[1] 傅萍[1] 孙石安[1] 邹利光[1] 杜鹤君 戴克正[1] 梁开运[1] 

机构地区:[1]第三军医大学新桥医院放射科,第三军医大学西南医院信息资料科,第三军医大学西南医院信息资料科放射科

出  处:《中华放射学杂志》1995年第5期300-302,共3页Chinese Journal of Radiology

摘  要:作者介绍了自动洗片机定影液的配制方法及性能测定,6种胶片的定透时间及定影效果(密度差)。测定表明:自配定影液在温度30℃以上,冲洗全程150s(定影40s)以上,可满足胶片处理。2年来的实践证明,如此冲洗的胶片质量较好,能达到临床诊断要求。该药液配制方法简单,成本低廉,可替代商品套药在临床上的应用。This article introduced the prescription and quality control of a fixer solution for au-tomatic processor. The time for fixing and the effectiveness density difference were measured for 6 kinds of films;The results showed that the optimal processing temperature is >30℃, the fotal pro-cessing time is l50s(40s for fixing).Based on 2 years of clinical experience with this fixer solution,the authors concluded that this flxer solution yields films of diagnostic quality, is easily made and of low cost,therefore is a good substitute for the current commercial fixer for automatic processor.

关 键 词:X线胶片 质量控制 洗片机 定影液 配制 

分 类 号:R814.3[医药卫生—影像医学与核医学]

 