检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]兰州生物制品研究所诊断一室,湖北省汉川县卫生防疫站
出 处:《中华医学检验杂志》1995年第5期283-285,共3页
基 金:甘肃省中青年科技基金
摘 要:为寻求更简便、快速的伤寒病血清学诊断方法,以S.typhi0901菌株脂多糖(LPS)致敏胶乳,研制出伤寒血清学快速诊断胶乳试剂(LPS-Latex)。检测69份确诊伤寒病患者血清,阳性率为91.3%;高于肥达反应阳性率(79.7%)。分别以肥达反应、间接血凝试验、LPS-Latex三种方法检测562份疑似伤寒病患者血清,总符合率为93.41%。表明LPS-Latex法诊断伤寒病简便、快速,有较高敏感性和特异性。or seeking simple, rapid serodiagnostic assay for typhoid fever,a latex reagent was prepared by sensitizing latex with S. typhi O901 lipopolysaccharide (LPS). Slide latex agglutination test was carried out to detect anti- LPS antibody in serum samples diluted 1: 10.Testing serum samples from 69 patients proven to be typhoid fever showed that the positive rate of LPS~latex test was 91.3%,which was much higher than that of the Widal test(79.7%).Of 562 serum samples from patients cinically suspectes as typhoid fever,the results of the Widal test,LPS-latex and LPS-PHA showed coincidence rate of 93.41%. It was demonstrated that LPS-latex test could be applied in serodiagnosis of typhoid fever with high sensitivity and specificity.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.195