检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:俞英[1] 聂瑞华[2] 黄坚锋[3] 熊萍萍[3]
机构地区:[1]南昌大学应用化学所,南昌330047 [2]南昌大学机电系 [3]南昌大学应用化学研究所
出 处:《分析化学》1995年第8期903-906,共4页Chinese Journal of Analytical Chemistry
摘 要:本文建立了茜素红催化荧光测定痕量钒(V)的新方法.在λ_(ex)/λ_(em)=381/445(nm),由多目标罚函数单纯形法获得最佳实验条件为:1%茜素红6mL,1mol/L盐酸2.1mL,饱和KIO_4,1.8mL,反应温度85℃,反应时间15.30min,钒的检测下限为7×10^(-10)g/mL,反应对试剂及金属离子均为一级反应.方法用于水样和铬钒钢中钒的测定,结果满意.A catalytic fluorimetric determination of trace vanadium ( V ) using Alizarin Red was described. At λex/λem = 381/445 (nm),the experimental conditions were optimized by multi-object simplex method, they are 0. 1 % Alizarin red 6 mL, 1 mol/L HC1 2. 1 mL, saturated solution KIO4 1. 8 mL, temperature 85℃, reaction time of 153 min, the detection limit is 7×10-10g/mL. The mechanism of the reaction was studied, the reaction grades are one to alizarin red and V( V ). The method has been applied to the determination of trace V( V ) in the alloy samples with satisfactory results.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.140.248.104