低温堆水样中微量氢的测定  被引量:2

Determination of Microantont of Hy-drogen Dissolved in Cooling Water of HeatReactor

在线阅读下载全文

作  者:周海收[1] 温美娟[1] 辛仁轩[1] 

机构地区:[1]北京科技大学化学系,清华大学核研究院

出  处:《分析试验室》1995年第6期56-59,共4页Chinese Journal of Analysis Laboratory

摘  要:本文以氩载气洗提,气相色谱法测定低温核供热反应堆环路冷却水中的微量氢,可测定氢气最低浓度为0.20mL/LH_2O,在此浓度下,分析10次的精密度(相对标差)为10%。The extracdon and GC analysis of mi-cro amount of hydrogen dissolved in coolingwater of a heat reactor were studied.A sim-ple and rapid procedure for the preparationof aqueous samples for calibration and asampling device were designed.A methodwas given for the correction of the error re-sulted from the escaped nitrogen bubble insampling tube from the nitrogen-saturatedsample, Hydrogen at the concentration of 0.20mL/L H_2O can be determined with a pre-cision of 10%

关 键 词:气相色谱法 氢气  

分 类 号:O613.2[理学—无机化学] O657.71[理学—化学]

 