检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]天津大学精密仪器系
出 处:《仪器仪表学报》1989年第4期343-350,共8页Chinese Journal of Scientific Instrument
摘 要:本文阐述在可见区(25000~10000Cm^(-1),即400~1000mm)工作的傅里叶变换光谱仪的设计方法及实验样机的研制结果;提出了光学二倍频法、舍弃白光干涉仪、相位校正与切趾匹配的正确选择,采用立方角镜等新设计思想,探讨了它们的优点和实现方法。This paper reports design methods of a Fourier transform spec-trometer in visible region(25000~1000 Cm^(-1))in detail.The quality and theexperimental results of a trial instrument is also introduced.Some new opinions for projection and new optical systems,such as opticalfrequence doubling,substitution of reversible counter for white light interf-erometer,correct matching between phase correction and apodizition,replece-ment plane mirrors by cube corner reflectors,are suggested,and their advat-ages also discussed.The results of experiments show that it is reasonable to develop a Fouriertransform spectrometer under relative simple technical conditions and relativecheaply.