检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]贵阳医学院附院内分泌科
出 处:《贵阳医学院学报》1995年第2期100-103,共4页Journal of Guiyang Medical College
摘 要:用免疫放射法(IRMA)测定了378例各种甲状腺疾病及非甲状腺疾病(NTI)患者血清TSH以及T_3、T_4和FT_4水平。结果:未治疗或症状未控制的甲亢患者血清TSH明显低于对照组,甲亢治愈者则恢复正常。甲减者TSH变化与其临床表现相一致。在碘缺乏病区TSH-IRMA能较T_3、T_4更好的反映居民的碘营养状况。在NTI时虽有T_3、T_4的改变,但TSH-IRMA和FT_4结果大多为正常。本文表明TSH-IRMA在评估甲状腺功能状态时有较好的敏感性及特异性。Serum TSH levels were measured by a sensitive immunoradiometric assay(IRMA) and serum T3, T4 and FT4 levels were also measured by radioimmunoassay (RIA)in 378 patients with various thyroid diseases or nonthyroidal illness(NTI). The results showed that serum TSH levels were significantly lower in untreated and non-controlled hyperthyroid patients as compared with controls.The subnormal TSH values were found to become normal in clinical euthyroid patients.The changes of serum TSH leveis in the patients with hypothyroidism were consistency with their clinical symptoms.The TSH-IRMA was a better indicator as the iodine nutrition condition of the inhabitants in the iodine deficiency disorders areas than T3 and T4 assay. Although some of patients with NTI had abnormal T3 and T4 levels, most of them still had normal TSH-IRMA and FT4 levels.This study suggested that TSH-IRMA presented a good sensitivity and specificity in assessment of thyroid function starus.