检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘学勇[1] 马长勤[1] 蒋德华[1] 沈静兰[1]
机构地区:[1]山东大学化学院,济南250100
出 处:《化学学报》1995年第8期801-804,共4页Acta Chimica Sinica
摘 要:本文采用KTiOPO_4单晶薄片作为离子活性传感膜,制备了钾离子选择性电极.20℃时,其线性响应范围为1.2×10^(-5)~1.0mol·dm^(-3)氯化钾溶液,平均响应斜率为58mV/-1ga_K,对钠离子的电位选择性系数为4.0×10^(-4).该电极的优点是电极斜率受酸度变化影响小,稳定性和重现性好,寿命长.A new potassium ion selective electrode is proposed, in which the KTiOPO4 single crystal membrane is used as the electroactive material. The slope of response is determined to be 58mV/ -lgaK by means of computer fitting. The selective coefficients in relation to Na+ is 4.0×10-4. The advantages of this electrode are that its slope can be hardly influenced by the variation of the pH value; its stability, repeatability and its long lifetime as well.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.229