庆大霉素和金霉素废水的处理试验研究  被引量:4

Study on the Treatment of Gentamycin and Aureomycin Wastewaters and the Measures for Pollution Control

在线阅读下载全文

作  者:周平[1] 钱易[1] 苏诚艺[1] 李炳伟[1] 

机构地区:[1]清华大学环境工程系,中国环境科学研究院

出  处:《环境科学》1995年第5期45-47,共3页Environmental Science

摘  要:对庆大霉素、金霉素及其混合废水的厌氧、好氧处理进行静态试验。结果表明,对于COD为19240mg/L的庆大霉素废水,当厌氧反应时间为3d,好氧10h时,COD去除率为98.4%;COD为7740mg/L的庆大霉素和金霉素混合废水(1:2),厌氧处理2d,好氧10h时,COD去除95.8%;庆大霉素废水厌氧处理3d,金霉素废水厌氧处理6h,再将这2种废水混合进行好氧处理4h,其最终出水COD可小于300mg/L。A gentamycin wastewater, an aureomycinwastewater and a mixture of both wastewaterswere subjected to an anaerobic treatment ,an aerobic treatment or a combination of . both treatments in batch experiments. A COD removal of98. 4 % was given when a gentamycin wastewaterwith a COD concentration of 19240 mg/L wassubjected to an anaerobic treatment for 3 d andthen to an aerobic treatment for 10 h. A COD removal Of 95. 8% was given when a mixture ofgentamycin wastewater and aureomycin wastewater (1: 2) with a COD concentration of 7740mg/L was subjected to an anaerobic treatment for2 d and then to an aerobic treatment for 10 h.The COD concentration in final effluent could bereduced to less than 300 mg/L when the gentamyCin wastewater after an anaerobic treatmentfor 3d was combined with the aureomycinwastewater after an anaerobic treatment for 6 hand then subjected to an aerobic treatment for 4h.

关 键 词:庆大霉素 金霉素 厌氧 好氧 静态试验 废水处理 

分 类 号:X789.03[环境科学与工程—环境工程]

 